Chiller Won't Turn On
- Verify the chiller is plugged into an active power source.
- Reset the power plug by pressing the 'RESET' button on the breaker.
- Ensure the power switch is in the 'On' position.
- Check and replace the fuse with a 15A fuse if necessary.
Leaking Hose Connections
- Tighten all connections.
- Ensure gaskets are intact and undamaged.
O2 Error Message
- Filter Cleaning: Clean the mesh filter with a soft sponge. Replace the micron filter if needed.
- Check for Air Leaks: Ensure all parts are tightened. Tighten hose connections and elbow connectors with a wrench. Check for missing gaskets/o-rings in hose ends, mesh filter cup, and filter cartridge.
- Clog Check: Inspect hose connections for clogs and clear any obstructions. Check the valve inside the chiller.
- Vacuum Seal: Listen for a rattling sound from the chiller, which may indicate a broken vacuum seal. Contact support for a replacement part.
FL Error Message
- Inspect hose connections for clogs.
- Ensure all components are tightened.
- Check the valve inside the chiller.
- Contact support if the problem persists.